drain line Archives - CellarCool® https://www.cellarcool.com/tag/drain-line/ Thu, 21 May 2026 19:50:41 +0000 en-US hourly 1 https://wordpress.org/?v=7.0.4 https://www.cellarcool.com/wp-content/uploads/2021/08/cropped-CC-32x32.png drain line Archives - CellarCool® https://www.cellarcool.com/tag/drain-line/ 32 32 Cellar Humidity & Condensate https://www.cellarcool.com/educational/cellar-humidity-condensate/ https://www.cellarcool.com/educational/cellar-humidity-condensate/#respond Wed, 13 Oct 2021 12:07:06 +0000 https://whisperkool.com/?p=13349 Some of our clients are unaware of why their cooling system will produce water condensate through the drain line. This water is a byproduct of your cooling system stripping excess humidity from the air inside your cellar. This feature was added to protect your collection...

The post Cellar Humidity & Condensate appeared first on CellarCool®.

]]>
Some of our clients are unaware of why their cooling system will produce water condensate through the drain line.

This water is a byproduct of your cooling system stripping excess humidity from the air inside your cellar. This feature was added to protect your collection from the side effects of long-term storage in a high humidity environment.

How CellarCool Systems Manage Cellar Humidity.Humidity Control

The key difference between CellarCool systems and traditional air conditioner units is the maintenance of well-conditioned humidity. Regular air conditioning units are designed to cool as quickly as possible. As a result, humidity is removed below acceptable wine storage levels. CellarCool achieves optimal results by gently cooling the air within your cellar at a slower rate, thus maintaining optimal humidity levels for the long-term storage of fine wines.

Producing Too Much Water?

If you are experiencing abnormally high volumes of water dispensing from your system’s drain line, your cellar is more than likely suffering from improper vapor barrier applications.
Relative Humidity

In high humidity areas (75%-90% relative humidity) of the country, moisture will frequently travel through the walls (especially in underground applications where materials like concrete or cinderblock are used) and enter the cellar. When creating your wine storage area, it is crucial to research your area’s climate to identify potential areas of concern. We suggest maintaining humidity levels near 55% since higher humidity levels can contradict the cooling process and make it harder to maintain temperature.

What Can You Do To Prepare Your Cellar For Humidity?

Vapor Barrier – 

When building your cellar, a vapor barrier is necessary for the efficient cooling of the cellar environment. The barrier acts as a defense to unwanted moisture coming in or escaping out of your wine cellar environment.

Sealing Your Cellar –

Properly sealing your cellar environment will prevent unwanted humidity from leaking into your cellar and causing your unit to expend more of its capacity to work to strip this excess moisture. Areas of concern are as follows: doors, wall joints, and the cellar’s flooring, & ceiling sealing seal. These areas should all be properly sealed with recommended materials.

An Important Note To Keep In Mind.

When a cooling unit strips excess humidity out of the air within the cellar, it is using a percentage of its overall capacity to do that. For example, if your system was rated to run 50% of the time to cool the heat load of the cellar, it will use an additional 10%-20% of its capacity to work to strip the unwanted humidity from the air, when proper humidity prevention methods are not taken. This is extremely important to note when pertaining to the runtime of your system and the amount of liquid drainage from your cooling system.

The post Cellar Humidity & Condensate appeared first on CellarCool®.

]]>
https://www.cellarcool.com/educational/cellar-humidity-condensate/feed/ 0
Importance of Annual HVAC Technician Cooling System Inspection/Maintenance https://www.cellarcool.com/support/importance-of-annual-hvac-technician-cooling-system-inspection-maintenance/ https://www.cellarcool.com/support/importance-of-annual-hvac-technician-cooling-system-inspection-maintenance/#respond Mon, 27 Sep 2021 06:00:32 +0000 https://whisperkool.com/?p=8164 It’s important to have an HVAC technician regularly inspect your unit to make sure that it’s working correctly. We thought we’d take some time to explain exactly what an HVAC-R inspection entails and why it’s so important to get one annually. NOTE: Accessibility varies depending...

The post Importance of Annual HVAC Technician Cooling System Inspection/Maintenance appeared first on CellarCool®.

]]>
It’s important to have an HVAC technician regularly inspect your unit to make sure that it’s working correctly. We thought we’d take some time to explain exactly what an HVAC-R inspection entails and why it’s so important to get one annually.

NOTE: Accessibility varies depending on the type of CellarCool unit you have. The following information pertains to split systems. For self-contained systems, HVAC technicians will be able to clean the drain line, coils, and/or filters and visually inspect components such as fans.

When an HVAC technician inspects your unit, he or she will:

1. Clean.

The HVAC technician will perform a comprehensive cleaning of the unit. This is especially important for split systems, as only qualified HVAC-R technicians (the “R” stands for “refrigeration”) can take the system’s housing off under warranty. The technician will clean and/or replace any filters in the ducting or in the unit itself. He or she will also clean the evaporator and condenser coils. The technician will clean the drip tray (removing any mold or bacterial build-up) and the drain line (removing any vermin- or mold-related clogs). Finally, the HVAC technician will wipe down the evaporator unit and condensing unit.

2. Test.

The technician will perform two kinds of functionality tests on your CellarCool ystem. The first is a “control functionality test.” This test ensures the controller is working properly. The technician will turn the controller on and off and attempt to temporarily readjust the set point. This will ensure that the controller responds properly and instructs the unit to begin cooling the cellar when it senses a preset temperature change. The second is a condensing unit functionality test. The technician will test the system to ensure the condensing unit and its various components are functioning properly.

3. Inspect.

The line set is the copper tubes that transfer refrigerant between the condensing unit and the evaporator unit. The technician will inspect this line set to ensure that it’s not leaking and that it’s properly insulated. He or she will also inspect all wires and wiring connections to make sure they’re sound. Finally, the HVAC technician will check the sight glass to ensure the refrigerant levels are where they should be. If necessary, the technician will top off the cooling unit’s refrigerant charge.

Some of the problems this annual inspection may catch and/or prevent include:

1. Drainage issues: When inspecting the unit, an HVAC technician will pay special attention to the drip tray and drain line. Ensuring these are kept clean and clear of obstructions will prevent water damage to your unit and your wine cellar.

2. Unit failures: Regular inspections ensure that operational problems are caught in time. For example, if the cooling fan on the condensing unit burns out, this will eventually cause the compressor to burn out. Annual inspections can help HVAC technicians catch these small problems before they cause premature failure of the unit. The technician will also check the integrity of all wiring.

3. Loss of cooling capacity: By thoroughly cleaning the coils, the technician will ensure your cooling unit’s maximum efficiency and longevity. Dust on the coils and clogged filters will prevent the unit from cooling your cellar to the desired temperature. Regular inspections and cleanings help to alleviate these problems.

Long story short, it’s essential to have your cooling unit regularly inspected by a qualified HVAC-R technician. The technician will be able to clean and perform routine maintenance upon the unit. He or she can also top off refrigerant charge and catch potentially serious issues before they become a problem.

 

The post Importance of Annual HVAC Technician Cooling System Inspection/Maintenance appeared first on CellarCool®.

]]>
https://www.cellarcool.com/support/importance-of-annual-hvac-technician-cooling-system-inspection-maintenance/feed/ 0
Improve Unit Drainage with Rigid Drain Line, Strainer, and Condensate Pump https://www.cellarcool.com/support/improve-unit-drainage-with-rigid-drain-line-strainer-and-condensate-pump/ https://www.cellarcool.com/support/improve-unit-drainage-with-rigid-drain-line-strainer-and-condensate-pump/#respond Sun, 01 Aug 2021 06:00:07 +0000 https://whisperkool.com/?p=8167 The post Improve Unit Drainage with Rigid Drain Line, Strainer, and Condensate Pump appeared first on CellarCool®.

]]>

CellarCool prides itself on helping our customers and educating them about proper cellar construction and cooling unit care. We also intend to help our customers prevent common technical issues that may arise during the course of a unit’s operational life. One of the most persistent problems our customer service team has encountered is clogged drain lines. We’ve put our heads together and come up with a list of modifications you can make to your unit, prior to installation, that will help prevent drain line clogging issues. These modifications include rigid drain lines, drain line strainers, and a condensate pump.

Pre-Installation Modification #1: Rigid Drain Line

drain line drainage condensate pump condensation drip tray whisperkool

CellarCool’s ceiling-mounted units, which include built-in condensate pumps, use 1/4″ clear plastic drain lines. Sometimes, however, during installations, this drain line can accidentally become kinked. This inhibits the flow of condensate from your unit’s drip tray to the proper condensate disposal area. If the drain line becomes so kinked that water cannot pass through it, the drip tray in your unit may overflow. This can cause water damage to the unit and possibly your cellar’s wine racks, your bottle labels, and perhaps the floor or walls of the cellar itself.

A remedy to this problem is rigid drain lines, made of copper or PVC plastic. Copper or PVC drain lines are much less likely to kink, minimizing the danger of accidental kinking during installation. As long as care is taken to ensure that these drain lines are kept clean and clog-free, rigid drain lines should provide you with a reliable and consistent way for your ceiling-mounted unit to dispose of excess condensate.

Pre-Installation Modification #2: Drain Line Strainer

drainage drain line strainer copper suction whisperkool condensate drip tray clogs

Besides kinking, another cause of drain line obstructions is insects. Insects, especially in dry areas of the United States, migrate to moist areas. The water in drain lines is a prime target. Sometimes bugs can climb inside drain lines. There, they become stuck and die, resulting in an eventual drain line blockage. Purchasing a drain line strainer, such as the above strainer from Cole-Parmer, can prevent insects from climbing inside drain lines and blocking them.

Pre-Installation Modification #3: External Condensate Pump

condensate pump drainage drain line whisperkool wine cellar cooling unit

The final way to upgrade your cooling unit’s drainage system prior to installation is to purchase an external condensate pump. This pump easily attaches to the outside of a CellarCool evaporator unit. If you live in a high humidity area and anticipate that your unit will produce lots of moisture, an external condensate pump is a great way to prevent water from overflowing the drain pan and causing damage to your wine cellar.

These are all ways you can improve the drainage of your CellarCool unit prior to its installation. Rigid drain lines will prevent kinks. Drain line strainers will prevent vermin-related clogs. And the external condensate pump kit can pump excess condensate to a safe disposal location.

The post Improve Unit Drainage with Rigid Drain Line, Strainer, and Condensate Pump appeared first on CellarCool®.

]]>
https://www.cellarcool.com/support/improve-unit-drainage-with-rigid-drain-line-strainer-and-condensate-pump/feed/ 0
CellarCool Condensate Pumps https://www.cellarcool.com/support/condensate-pumps/ https://www.cellarcool.com/support/condensate-pumps/#respond Mon, 07 Jun 2021 06:00:50 +0000 https://whisperkool.com/?p=9277 The CellarCool condensate pump is a small condensate removal pump that is installed in our Ceiling Mount units. This pump facilitates the removal of condensate from the internal drip tray and routes it away from the unit—preferably via a rigid drain line (PEX or CPVC)....

The post CellarCool Condensate Pumps appeared first on CellarCool®.

]]>
The CellarCool condensate pump is a small condensate removal pump that is installed in our Ceiling Mount units. This pump facilitates the removal of condensate from the internal drip tray and routes it away from the unit—preferably via a rigid drain line (PEX or CPVC).

Advantages of a Condensate Pump

CellarCool units can, under certain circumstances, produce moisture in the form of condensate during normal operation. This moisture collects in a tray inside the unit. The water is then routed out of the unit via a gravity-fed internal drain tube.

In humid environments, occasionally, excess condensate may be produced. This can cause the drip tray to overflow. This, in turn, may cause water damage to the cellar, the racking, or the unit itself.

Our condensate pump uses a reservoir that contains a thermistor to sense the condensate produced by the unit. This thermistor determines when the water in the drip tray has risen too high. The thermistor engages the pump, which removes the excess condensate from the drip tray. By means of a rigid drain line, the condensate drains to a safe location.

Premature Pump Failures

Environmental factors can play a role in causing a condensate pump to prematurely fail. Buildup of mold or bacterial growth in the drip tray can clog the condensate pump and cause it to malfunction. Sometimes, also, the timing of the unit’s installation can be a factor. Sometimes CellarCool systems are installed in homes before the home’s construction is complete. During normal operation, the unit will sometimes take in wood and drywall dust and other construction debris. This debris sometimes contaminates the drip tray and clogs the condensate pump’s lines.

Other factors which can lead to premature condensate pump failures include:

– kinks in the drain line
– restrictions or clogs in the drain line
– sagging (when part of the drain line droops or sags, creating an uphill slope in part of the line, prohibiting water from draining naturally)
– freezing (in cold climates, if the drain line is routed out of doors, water freezing in the line can become an issue)
– exceeding specified application parameters during installation (the drain line must have no more than a 15-foot vertical rise and 50-foot horizontal run)

Conclusion

To conclude, condensate pumps—which come standard on Cellar Ceiling Mount units—help prevent leaks and water damage. When paired with a rigid drain line, they remove excess condensate from your unit. Environmental factors and installation oversights can sometimes lead to clogs and pump failure. We advise our customers to have their cooling units inspected regularly to ensure that they’re operating as efficiently as possible.

The post CellarCool Condensate Pumps appeared first on CellarCool®.

]]>
https://www.cellarcool.com/support/condensate-pumps/feed/ 0